application area  

Petrochemical, Power, Energy, Semiconductors, Steel, Optoelectronic Display, Deep processing of non-ferrous metals, Medical Pharmaceuticals, etc.
Product advantages  

CPVC production of runner plate frame,high weather resistance,long life design; Secondary glue injection to double O-ring sealing technology,prevent leakage; 2 in 2 out design,which can directly replace traditional ordinary flow channel products; Specially designed ion exchange membrane,extremely high ion selectivity,can achieve a large flow in a limited volume to produce high purity water; Designed service life of exceeding 60,000 hours.


Product introduction  

Feed water condition

Equivalent Conductivity (Containing CO2,Si)<40 μ s/cm
Operating Temperature5-45 °C
Inlet Pressure1.4-6.9 bar
Maxinum Total Chlorine(as Cl2)<0.02 ppm
Iron(as Fe)<0.01 ppm
Sulfide(S2-)<0.01 ppm
pH Value4-11
Total Hardness(as CaCO3)<1.0 ppm
Dissolved Organics (TOC,as C)<0.5 ppm
Silica(ppm as SiO2)<1.0 ppm
Total Exchange Anion(ppm as CaCO3)<25 ppm
OxidantNot detectable
Grease Not detectable

Produce water parameter

Working Voltage(V,DC)0-400
Working Current(A,DC)1.0-6.0
Suggest Feed Water pH8.0±0.25
Feed Water Pressure(bar)1.4-6.9
Operating Temperature(°C)5-45
Normal Flow Pressure Difference1.4-3.0
Recovery Rate(%)90-95
Product Resistivity(MΩ.cm)≥17
TOC Removal Rate (ppm)>95% (depending on feed water)
Silica Removal Rate >99% (depending on feed water)
Boron Removal Rate>95% (depending on feed water)
Sodium Ion Removal Rate>99%
Chloride Removal Rate>99%

Slection parameters   

ModelGF-DF05GF-DF10GF-DF20GF-DF30GF-DF50GF-DF80

Standard Flow rate

(m3/h)

0.5
1.12.03.35.18.0

Maximum Flow rate

(m3/h)

0.671.653.15.17.6710.0

Minimum Flow rate

(m3/h)

0.220.551.11.652.553.5

Dimensions

(L*W*H)(mm)

202*315*660280*315*660387*315*660572*315*660785*315*660918*315*660

Fixed Center Distance

(mm)

W1:215

L1:172

W1:215

L1:245

W1:215

L1:357

W1:215

L1:540

W1:215

L1:757

W1:215

L1:893

Product Net Weight

(kg)

415476105150176