GFPURE HT (High temperature)series of product have passed CE certification,
the assembly factory has passed
ISO 9001/2015 Quality Management system certification
ISO 14000 Environmental management system certification
ISO 45001 Occupational Health and Safety Management system certification
Minimum inlet water condition requirements
| Equivalent conductivity (including CO2 and silicon) | < 40us/cm |
| Operating temperature | 5-60℃ (41-140 °F) |
| Inlet pressure | 1.4-6.9 bar (20-100 psi) |
| Total chlorine maximum (as CL2) | < 0.02ppm |
| Iron (as Fe) | < 0.01ppm |
| Manganese (as Mn) | < 0.01ppm |
| Sulfide (S2-) | < 0.01ppm |
| PH | 4-11 |
| Total hardness (as CaCO3) | < 1.0ppm |
| Dissolved organic(TOC, as C) | < 0.5ppm |
| Silicon (ppm as SiO2) | < 1.0ppm |
| Total exchange anion (ppm as CaCO3) | < 25 |
| Oxidant | Not detectable |
| Grease | Not detectable |
Produce water parameter:
| Working voltage(V,DC) | 0-600 |
| Working current(A,DC) | 1.0-10.0 |
| Suggest feed water pH | 7.5-8.0 |
| Feed water pressure(bar) | 1.4-6.9 |
| Operating temperature(°C) | 5-60 |
| Normal flow pressure difference(bar) | 1.4-2.8 |
| Recovery rate(%) | 90-95 |
| Product resistivity(MΩ.cm) | ≥17 |
| TOC removal rate(ppm) | >95% |
| Silica removal rate | >99% |
| Boron removal rate | >98% |
| Sodium ion removal rate | >99% |
| Chloride removal rate | >99% |